Recognize the technical principles of line distributed fault diagnostic devices and double-ended traveling wave ranging algorithms for localization

Author: Click:224 Time:2025-01-02

With the rapid development of the electric power industry and the continuous expansion of the power grid, the operating environment of transmission li

With the rapid development of the electric power industry and the continuous expansion of the power grid, the operating environment of transmission lines is becoming more and more complex, and the risk of failure also increases. In order to guarantee the continuity and reliability of power supply, our company has developed a transmission line Distributed Fault Diagnostic Device DX-WPS100-GZ01. Below, I would like to briefly explain the technical principle, technical requirements and algorithmic features of the device.



I. Technical principles

The technical principle of the distributed fault location device for transmission lines is mainly based on distributed traveling wave ranging technology, data communication technology and intelligent algorithms. By installing multiple monitoring terminals on transmission line conductors to achieve all-round coverage of the line, it can monitor real-time line traveling wave current, fault current waveform data, clock data, and quickly alarm when a fault occurs, locate the fault point, identify the type of fault, and reduce the time wasted in blind investigation. In addition, the monitoring terminal is connected to the monitoring platform center through wireless communication technology, which facilitates quick response and disposal of emergencies, and significantly improves the maintenance efficiency and power supply reliability of transmission lines.


II. Technical requirements

1.    Devices and the full range of Internet of Things platform and its communication loop should be in line with the Q/CSG1204009 in the online monitoring system for power equipment security protection requirements;

2.    Components installed on the line should take anti-vibration, anti-loosening measures, not wear and tear or other injuries to the conductor and ground, should not significantly reduce the phase-to-phase distance, the distance to the ground and to the electrical clearance of the tower, and to meet the design requirements;

3.    Formal operation will not affect the operational safety of transmission lines.


III. Algorithmic features

1.    Double-ended traveling wave ranging algorithm: double-ended traveling wave ranging is installed at both ends of the line are a set of monitoring terminals, through the detection of a traveling wave arrives at the two ends of the time difference to calculate the location of the fault point. Traveling wave ranging algorithm involves the identification of traveling waves, which contain a large number of high-frequency components, the measurement of the traveling wave head time point is an important factor affecting the ranging accuracy. Currently, the algorithm with higher accuracy is to use the phase mode transform to obtain the line mode components that are less affected by the line parameters, and then use the wavelet transform to identify the traveling wave head.

2.    Deep Learning and Intelligent Algorithms: Deep learning techniques are used, especially Convolutional Neural Networks (CNN), Deep Belief Networks (DBN), Recurrent Neural Networks (RNN) and so on, and these models are able to extract higher-order, abstract, and detailed information about the fault features from a large amount of data, and classify the faults.

3.    Automated Repair: Based on the type and cause of the failure, the system can The system provides targeted repair recommendations and assists technicians in troubleshooting.



Related recommendations

The online monitoring, distributed fault location and cable online monitoring equipment for power transmission and distribution lines launched by SHENZHEN DINSEE SMART TECHNOLOGY CO.,LTD. has been widely used in Southern Power Grid and State Grid, and has achieved good results.

Record No.: Yue ICP Bei 2022070794-1 | Website Map XML Map

主站蜘蛛池模板: 乱人伦无码中文视频在线| 特殊重囗味sm在线观看无码| 精品无人区无码乱码大片国产| 成人国产精品日本在线| 久久99精品国产免费观观| 国产精品自在拍首页视频8| 欧美亚洲日本日韩在线| 免费无码va一区二区三区| 2021国产精品成人免费视频| 天天澡天天添天天摸97影院| 亚洲中文字幕va福利| 天天鲁一鲁摸一摸爽一爽| 中文字幕亚洲精品乱码| 7777久久亚洲中文字幕蜜桃| 亚洲日韩性欧美中文字幕| 中文无码乱人伦中文视频播放| 亚洲精品伊人久久久大香| 成年美女看的黄网站色戒 | 国产精品亚洲a∨天堂| 国产艳妇av在线出轨| 亚洲天天做日日做天天欢毛片| 国产欧美日韩精品专区| 国产欧美va天堂在线观看视频| 美女视频黄又黄又免费| 日本不卡一区二区三区在线| 国精品无码一区二区三区在线蜜臀 | 国产成人综合野草| 秋霞电影网午夜鲁丝片无码| 国产成 人 综合 亚洲奶水| 成人影院yy111111在线| 亚洲熟妇无码av在| 影音先锋无码aⅴ男人资源站 | 人人妻人人澡人人爽曰本| 丝袜自慰一区二区三区| 秋霞最新高清无码鲁丝片| 亚洲国产五月综合网| 中文日韩亚洲欧美制服| 97人人模人人爽人人喊电影| 久久国内精品一区二区三区| a级大胆欧美人体大胆666| 亚洲h精品动漫在线观看|